Gbona Tita 3 nyorisi EKG 24Hour Holter
Get Latest PriceMin. Bere fun: | 1 Set/Sets |
Aṣeṣe No.: SDD-A07
Brand: Igba
Holter Monitor Ecg ọja Digital Holter Ecg Machine
Iṣiro Software Iṣiro
1. Oṣuwọn ti ṣayẹwo igbi RR si 99.9%, eyiti o mu deede ti onínọmbà laisi igbi pipadanu.
Iṣẹ AI histogram eyiti o le ṣe iyatọ taara oriṣiriṣi ECG ajeji ajeji eyiti o le ṣe itupalẹ yarayara.
3. Dynamic ECG function “ Channel Correct ” , eyiti o le ṣe atunṣe wọsi aṣiṣe ti o mu ki onínọmbà naa pe deede.
4.Lorenz ati iṣẹ onínọmbà Demix, eyiti o le ṣe itupalẹ yiyara diẹ sii, diẹ sii deede. Nikan egbogi irú le ti wa ni patapata atupale ni 10 min, eyi ti o le din awọn ologun 's iṣẹ.
5.ST le ṣe afihan ni ọpọlọpọ iru fọọmu, eyiti o ni idaniloju pe itupalẹ aworan atọka ST-Trends ni oye, ṣiṣe akiyesi gbogbo tabi apakan ST oriṣiriṣi lati ṣe itupalẹ agbegbe kan pato ti ischemia myocardial.
6. Iṣẹ fibrillation ti ile-iwe le jẹ idanimọ laifọwọyi ati pe o le ṣe iyatọ ọran ọran fibrillation atrial, fun imọran ati ṣe agbejade ijabọ onínọmbà.
7. Iṣẹ Atọka Rirẹ Alailẹgbẹ Alailẹgbẹ, eyiti o le ṣe idajọ itọka ti Rirẹ Cardiac .A le rii awọn ẹgbẹ ti o ni ewu giga ati pe a le mu itọju ilowosi ni kutukutu nipasẹ itọka, eyiti o le ṣe idajọ ọjọ-ori ọkan daradara ati ṣe asọtẹlẹ SCD (Iku-iku Cardiac Lojiji).
8. Iṣẹ onínọmbà P-igbi, eyiti o le ṣayẹwo arrhythmia inu ọkan (bii AVB).
9. Gẹgẹbi ibeere ti awọn alaisan, awọn aṣayan le yan larọwọto lakoko ijabọ titẹjade, eyiti o le fipamọ oniwosan 'S akoko
10. ECG le ti wa ni tejede nipa orisirisi awọn fọọmu ni ibamu si awọn olumulo 's ibeere.
11. Iṣẹ onínọmbà Aladani, eyiti o le ṣe itupalẹ oriṣiriṣi awọn ẹrọ ti a fi sii ara (bii AAI, VVI, DDD).
12. Eto onínọmbà okeerẹ ti ẹya iduro-nikan pẹlu ẹya nẹtiwọọki, awọn olumulo le yan larọwọto eyikeyi awoṣe.
13.Wa ati alailowaya ipo gbigbe nigbakanna, eyiti o dinku iṣẹ idiju.
14. Yiyi ECG ati eto onínọmbà ECG aimi, eyiti o dinku awọn iṣẹ ti eka.
15. Aṣẹ Aago ati Išẹ Aṣẹ Igbohunsafẹfẹ lori module HRV le ṣe afihan ipa iwọntunwọnsi ti aanu ati parasympathetic si oṣuwọn ọkan.
Iṣẹ 16.HRT le ṣe asọtẹlẹ infarction myocardial eyiti o ni iye itọju.
17.ST iṣẹ eyiti o le ṣayẹwo akoko gangan ati ipari ti ischemia myocardial ni awọn wakati 24.
Channel |
12channels |
|
Storage Medium |
Flash Memory SD card |
|
Recording Time |
24/48 hours |
|
Dimensions |
70mm×50mm×20mm |
|
Data Transfer |
USB 2.0 / Bluetooth |
|
weight |
40g |
|
Recording accuracy |
<30s |
|
Input impedance |
≥9MΩ |
|
Short range recording (IPAD or PC) |
1000 segment |
|
Real-time 12channel ECG display |
||
Patient medical record management function |
||
Alarm function (Patient cables fall off) |
||
Dynamic and Static dual function |
||
Pacemaker detection |
||
Batteries |
1 AA alkaline battery |
Gbólólólóhùn Asiri: Asiri rẹ ṣe pataki pupọ si wa. Ile-iṣẹ wa ṣe ileri lati ṣe sọ alaye ti ara ẹni si eyikeyi ifihan pẹlu awọn igbanilaaye rẹ.